A carbositall electrode modified with a SiO2-hemoglobin-gold film as a promising biosensing element
Autor: | T. S. Rozhanchuk, O. A. Egorov, O. Yu. Tananaiko, E. A. Mazurenko |
---|---|
Rok vydání: | 2012 |
Předmět: | |
Zdroj: | Journal of Analytical Chemistry. 67:156-162 |
ISSN: | 1608-3199 1061-9348 |
Popis: | The analytical prospects of a carbositall electrode modified with a film based on SiO2, hemoglobin (Hb), and gold nanoparticles (CSE SiO2-Hb-Au), prepared by deposition with an electrically generated catalyst, are reported. Hemoglobin on the surface of CSE SiO2-Hb-Au is shown to possess electrocatalytic activity toward dissolved oxygen, giving a rationale for the development of a rapid voltammetric procedure of O2 quantification with a detection limit of 0.1 mg/L. The inhibition activity of a number of nitrogen-containing organic substances to the catalytic current CSE SiO2-Hb-Au is studied. A voltammetric procedure is proposed for determination of the anti-flu drug rimantadine, 1-(1-adamantyl)ethylamine hydrochloride, with a detection limit of 0.4 mg/L. The procedure is applicable to the quantification of rimantadine in blood serum and saliva. |
Databáze: | OpenAIRE |
Externí odkaz: |