Imaging of collagen and proteoglycan in cartilage sections using Fourier transform infrared spectral imaging
Autor: | Richard G. Spencer, Kimberlee Potter, Linda H. Kidder, Ira W. Levin, E. Neil Lewis |
---|---|
Rok vydání: | 2001 |
Předmět: |
medicine.medical_specialty
Spectral signature Cartilage Immunology Type II collagen Infrared spectroscopy Mineralogy Chondrocyte Spectral imaging chemistry.chemical_compound medicine.anatomical_structure Rheumatology chemistry medicine Immunology and Allergy Pharmacology (medical) Chondroitin sulfate Fourier transform infrared spectroscopy Biomedical engineering |
Zdroj: | Arthritis & Rheumatism. 44:846-855 |
ISSN: | 1529-0131 0004-3591 |
Popis: | Objective To test the hypothesis that Fourier transform infrared (FTIR) spectral imaging, coupled with multivariate data processing techniques, can image the spatial distribution of matrix constituents in native and engineered cartilage samples. Methods Tissue sections from native and trypsin-digested bovine nasal cartilage (BNC) and from engineered cartilage, generated by chick sternal chondrocytes grown in a hollow fiber bioreactor, were placed either on calcium fluoride windows for FTIR analysis or gelatinized microscope slides for histologic analysis. Based on the assumption that cartilage is predominantly chondroitin sulfate (CS) and type II collagen, chemical images were extracted from FTIR spectral imaging data sets using 2 multivariate methods: the Euclidean distance algorithm and a least-squares approach. Results Least-squares analysis of the FTIR data of native BNC yielded a collagen content of 54 ± 13% and a CS content of 37 ± 16% (mean ± SD). Euclidean distance analysis of measurements made on trypsin-digested BNC demonstrated only trace amounts of CS. For engineered cartilage, the CS content was significantly lower (15 ± 5%), while the collagen content (73 ± 6%) was significantly higher than biochemically determined values (CS 34%, collagen 5%, protein 61%). These differences are due to the fact that the dimethylmethylene blue assay overestimated the CS content of the tissue because it is not specific for CS, while the FTIR spectral imaging technique overestimated the collagen content because it lacks specificity for different proteins. Conclusion FTIR spectral imaging combines histology-like spatial localization with the quantitative capability of bulk chemical analysis. For molecules with a unique spectral signature, such as CS, the FTIR technique coupled with multivariate analysis can define a unique spatial distribution. However, for some applications, the lack of specificity of this technique for different types of proteins may be a limitation. |
Databáze: | OpenAIRE |
Externí odkaz: |