Investigation of the combined efficiency of a solar/gas hybrid water heating system
Autor: | Saroj Karki, Karl R. Haapala, Brian M. Fronk |
---|---|
Rok vydání: | 2019 |
Předmět: |
Thermal efficiency
business.industry 020209 energy Nuclear engineering Energy Engineering and Power Technology 02 engineering and technology Combustion Solar energy Industrial and Manufacturing Engineering Heating system 020401 chemical engineering Natural gas Thermal Gas heater 0202 electrical engineering electronic engineering information engineering Environmental science 0204 chemical engineering Gas burner business |
Zdroj: | Applied Thermal Engineering. 149:1035-1043 |
ISSN: | 1359-4311 |
Popis: | In climate regions with large seasonal variations in solar radiation, such as the Pacific Northwest of the United States, a solar thermal energy collector might not economically satisfy year-round domestic water heating demands, requiring an auxiliary unit, such as a natural gas-fired water heater. Previous studies have shown that the burner efficiency of a gas-fired water heater varies depending on the log-mean temperature difference between the cold fluid (water) and the hot fluid (combustion gases). In a solar/gas hybrid water heating system, where solar collectors are used in conjunction with a gas-fired heater, the partial heating of water provided by solar input reduces the log-mean temperature difference value for the gas heater, reducing the efficiency of the gas burner. Since this efficiency reduction varies depending on the amount of pre-heating provided by solar energy input, it is difficult to accurately predict the actual cost and energy savings offered by solar/gas hybrid water heaters in different climates and operation scenarios. Hence, to predict the actual energy and cost savings under various design conditions, the performance of solar/gas hybrid systems must be better understood. The objective of this work is to experimentally determine the thermal performance of a solar/gas water hybrid water heating system with a 6.44 m2 flat plate solar collector array and a 22.3 kW natural gas burner in Corvallis, Oregon, USA. Under different temperature lifts and solar insolation values, the system was operated at three different modes of heating: solar, gas, and combined solar/gas mode. The overall system thermal efficiency value for each mode is calculated. The efficiency of the solar collector heating system was found to be 41.97%, 39.82%, and 35.05% at initial water temperature of 20, 30, and 51.5 °C, respectively. For initial water temperatures of 20, 30, and 51.5 °C, the efficiency of the gas burner was found to be 69.2%, 66.4%, and 65.5% at the HHV, and 76.7%, 73.6%, and 72.6% at the LHV of natural gas, respectively. In the combined solar/gas heating mode, the efficiency of the gas burner decreased with increasing solar fraction. For solar fractions of 4.93%, 9.40%, 11.39%, and 14.27%, the efficiency of the gas burner in terms of the HHV of natural gas was found to be of 69.08%, 66.80%, 66.17%, and 65.18%, respectively. Based on the experimental results, a configuration that would provide higher overall system efficiency for combined solar/gas heating is suggested. |
Databáze: | OpenAIRE |
Externí odkaz: |