HPGe and Scintillation Detectors Comparisons on Waste Drums Radioactivity Measurement
Autor: | Huang Wun-Jhih, Chin-Hsien Yeh, Ming-Chen Yuan, Hsiu-Wei Lee |
---|---|
Rok vydání: | 2016 |
Předmět: |
Scintillation
Radionuclide Nuclear engineering System of measurement Radioactive waste Drum Scintillator 010403 inorganic & nuclear chemistry 01 natural sciences Nuclear decommissioning 030218 nuclear medicine & medical imaging 0104 chemical sciences Semiconductor detector Nuclear physics 03 medical and health sciences 0302 clinical medicine Environmental science |
Zdroj: | Journal of Applied Mathematics and Physics. :1482-1487 |
ISSN: | 2327-4379 2327-4352 |
DOI: | 10.4236/jamp.2016.48154 |
Popis: | Two measurement systems, one being comprised of three HPGe detectors and the other being a 4π measurement system of the assembly of 10 sets of scintillation detectors, were compared for their measurement performance in operations of radioactive waste drum radioactivity measurement and clearance and release operation of decommissioning. The system features of the former were high costs, capable of identifying radionuclides, a measurement time of about 1000 sec. The system features of the latter were high sensibility, capable of identifying hotspots, a measurement time of about 100 sec. Various comparisons were made for the differences of the two systems on reference drums, whole-drum homogeneous and non-homogeneous metal drums and non-metal drums, whole-drums of different filling rates. The aim was to compare the differences of the two measurement systems in measuring radioactivity of critical radionuclides of 137Cs, 54Mn and 60Co. |