Performance of the delay lines of the delphi forward muon chambers

Autor: F. Defontaines, F. Stichelbaut, J. Kesteman, B. Goorens, E. Daubie, W. K. Van Doninck, Jacques Lemonne, O. Pingot, C. Bricman, L. Van Lancker, C. Poiret, C. Vander Velde, C. De Clercq, Stefaan Tavernier, L. Etienne, Jan Buytaert, J. H. Wickens
Rok vydání: 1989
Předmět:
Zdroj: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 283:792-795
ISSN: 0168-9002
DOI: 10.1016/0168-9002(89)91459-9
Popis: This report presents the performance of 4.35 m long delay lines used for position sensing along the anodes of drift chambers operated in the limited-streamer mode. Using only the time difference between the signals at the two ends of the delay line, a spatial resolution ranging from 1.5 to 2.5 mm is obtained, equivalent to 0.06% of the 4.35 m length of the line. The linearity of the time-to-distance relation is also studied.
Databáze: OpenAIRE