FIRE SAFETY OF CLT BUILDINGS IN CANADA
Autor: | Joseph Z Su |
---|---|
Rok vydání: | 2018 |
Předmět: |
040101 forestry
0106 biological sciences Computer science Forestry 04 agricultural and veterinary sciences Limiting Fire safety 01 natural sciences Civil engineering 010608 biotechnology Code (cryptography) Cross laminated timber 0401 agriculture forestry and fisheries General Materials Science Fire resistance Limit (mathematics) |
Zdroj: | Wood and Fiber Science. 50:102-109 |
ISSN: | 0735-6161 |
DOI: | 10.22382/wfs-2018-044 |
Popis: | This article provides an overview of the code requirements pertinent to large cross-laminated timber (CLT) buildings and the methods for meeting the requirements in Canada. Canadian building codes are objective-based. Compliance with the code is achieved by directly applying the acceptable solutions up to certain prescriptive building sizes (height and area) or by developing alternative solutions beyond the height and area limits. The fire safety design for a CLT building larger than the prescriptive limit must demonstrate that the building will achieve at least the minimum level of performance afforded by noncombustible construction in limiting the structural involvement in fire and contribution to the growth and spread of fire during the time required for occupant evacuation and emergency responses. |
Databáze: | OpenAIRE |
Externí odkaz: |