Non-invasive prediction of first catheter ablation outcome in persistent atrial fibrillation
Autor: | F. Dore, Julien Oster, C de Chillou, E. George, Jean-Marc Sellal |
---|---|
Rok vydání: | 2020 |
Předmět: |
medicine.medical_specialty
Univariate analysis Multivariate analysis business.industry medicine.medical_treatment Cardiomyopathy Atrial fibrillation Catheter ablation Ablation medicine.disease Pulmonary vein Internal medicine Cardiology Medicine Sinus rhythm Cardiology and Cardiovascular Medicine business |
Zdroj: | Archives of Cardiovascular Diseases Supplements. 12:105 |
ISSN: | 1878-6480 |
Popis: | Background Catheter ablation is a well-established therapy for atrial fibrillation. However, some patients are not responders, and there exists currently no method to efficiently select non-responding patients. Purpose The aim of this study is to look for predictive parameters of catheter ablation failure by analyzing the 12-lead surface electrocardiogram (ECG), combined with clinical parameters in patients undergoing the first ablation of persistent atrial fibrillation (PersAF). Methods Two hundred and fifty-eight patients with persistent AF (183 men; mean age 60,1 ± 9,8years) hospitalized for first catheter ablation were retrospectively recruited. A standard 12-lead ECG was acquired before the ablation procedure for each patient. Clinical parameters (CHA2DS2-VASc, LA volume, cardiomyopathy, left common trunk of pulmonary vein) and electrical parameters (f-wave amplitude and frequency) were analyzed and integrated in univariate and multivariate prediction models using a logistic regression technique. Results During an average follow-up of 13.2 ± 4.7 months, 129 patients were in sinus rhythm at 1 year of follow-up after ablation. A feature selection step was performed to select the most informative outcome predictor. A multivariate analysis combining clinical and electrical parameters obtained an AUC of 67.3, with sensitivity of 49.7% and positive predictive value of 52.3%. This model performed better than clinical and electrical parameters analyzed separately. Conclusions Two clinical parameters are associated with failure: LA volume and CHA2DS2-VASc score in univariate analysis. Combination of clinical and electrical parameters allowed for a better selection of non-responding patients. CHA2DS2-VASc score showed a significant correlation with predictive ablation failure, but further studies are needed to confirm that. |
Databáze: | OpenAIRE |
Externí odkaz: |