Incomplete Left Atrial Appendage Closure Successfully Treated With a Redo Procedure
Autor: | Francesco Tomassini, Michele Capriolo, Stefania Ferrua, Ferdinando Varbella, Gaetano Senatore, Paolo Giay Pron |
---|---|
Rok vydání: | 2020 |
Předmět: |
Appendage
medicine.medical_specialty medicine.diagnostic_test business.industry Closure (topology) Atrial fibrillation General Medicine 030204 cardiovascular system & hematology Transesophageal echocardiogram medicine.disease 03 medical and health sciences 0302 clinical medicine Left atrial Internal medicine Occlusion cardiovascular system Cardiology Medicine cardiovascular diseases 030212 general & internal medicine Cardiology and Cardiovascular Medicine business |
Zdroj: | Cardiovascular Revascularization Medicine. 21:69-72 |
ISSN: | 1553-8389 |
DOI: | 10.1016/j.carrev.2020.05.033 |
Popis: | A 68 year's old man with permanent atrial fibrillation, underwent a left atrial appendage closure because of high bleeding risk. However, after one month, an incomplete occlusion of the left atrial appendage due to a too deep position of the device, was detected by a transesophageal echocardiogram. Considering the residual high risk of thrombi formation, a new different device was successfully implanted with a correct closure of the appendage. |