Towards the SQL: Status of the direct thermal-noise measurements at the ANU
Autor: | Malcolm B. Gray, C. M. Mow-Lowry, S Goßler, J Cumpston, David E. McClelland, B. J. J. Slagmolen |
---|---|
Rok vydání: | 2006 |
Předmět: | |
Zdroj: | Journal of Physics: Conference Series. 32:362-367 |
ISSN: | 1742-6596 1742-6588 |
Popis: | We present the preliminary results for an experiment that aims to perform direct measurements of suspension thermal noise. The experiment is based on a niobium flexure membrane approximately 200 µm thickness that is operated as a stable inverted pendulum. A 0.25 g mirror suspended by this flexure membrane is used as the end mirror of a Fabry-Perot test cavity. This test cavity has a length of 12mm and a finesse of about 800. It is mounted at the lowest stage of a quadruple cascaded pendulum suspension, enclosed in a high-vacuum envelope. The length of test cavity is stabilized with 1Hz bandwidth to a Nd:YAG laser, which itself is stabilized with high bandwidth to the length of a suspended Zerodur reference cavity of finesse 6000. |
Databáze: | OpenAIRE |