Popis: |
Background Sagittal split ramus osteotomy (SSRO) can be associated with postoperative neurosensory disturbances. This study aimed to evaluate the effectiveness of computer-assisted SSRO in reducing the incidence and severity of neurosensory alterations, using a surgical guide fabricated by computer-aided design and rapid prototyping (to guide bone cutting lateral to the inferior alveolar nerve). Methods A prospective double-blind, randomized controlled, clinical trial of computer-assisted SSRO vs conventional SSRO (assigned in a split-mouth design) in eight patients, mean age 23 (range 18–30) years, who participated in one session preoperatively and three sessions at 1 week and 1, 3 and 6 months postoperatively. At each session, subjective oral sensation was scored and quantitative sensory tests were performed. Neurosensory changes were compared between the two sides. Results The results showed that on the computer-assisted SSRO sides, patients had lower postoperative abnormal thresholds for the Semmes–Weinstein monofilaments on lower lip and chin (p |