Autor: |
Nur Aira Abd Rahman, Nor Arymaswati Abdullah, Lojius Lombigit |
Rok vydání: |
2014 |
Předmět: |
|
Zdroj: |
AIP Conference Proceedings. |
ISSN: |
0094-243X |
DOI: |
10.1063/1.4866107 |
Popis: |
An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|