Precise dental ablation using ultra-short-pulsed 1552nm laser

Autor: Molly Fahey, Ogugua Onyejekwe, Kunal Mitra, H. Lawrence Mason
Rok vydání: 2008
Předmět:
Zdroj: International Journal of Heat and Mass Transfer. 51:5732-5739
ISSN: 0017-9310
DOI: 10.1016/j.ijheatmasstransfer.2008.04.034
Popis: A desktop diode pulsed laser having pulse width of 1.3 ps and wavelength of 1552 nm is utilized for precise targeted ablation of dentin, enamel, and composite material while minimizing thermal damage to the surrounding healthy tissue and nerve endings. A thermal imaging camera is used to measure the dental surface temperature rise during ablation. Following ablation, scanning electron microscopy (SEM) and optical microscopy are used to determine the quality of ablation and the volumetric ablation rate as a function of laser parameters. Surface temperature measurements are compared with the numerical modeling results obtained using the transient heat conduction equation. A good agreement between experimental and modeling results for the surface temperature is obtained which ensures accurate prediction of the temperature distribution throughout the tooth using numerical models. The SEM generates images of precise ablation of each dental material when the optimal laser parameters are used and the sample is scanned at a velocity to limit the number of overlapping pulses. During the ablation process there is minimal collateral damage to the surrounding healthy tissue and minimal heat spread throughout the tooth thus preserving the integrity of the pulp.
Databáze: OpenAIRE