Autor: |
Toshiyuki Saito, Takuya Ogawa, Masao Itatani, Takahiro Hayashi, Chihiro Narazaki, Kentaro Tsuchihashi |
Rok vydání: |
2012 |
Předmět: |
|
Zdroj: |
International Journal of Pressure Vessels and Piping. :61-68 |
ISSN: |
0308-0161 |
DOI: |
10.1016/j.ijpvp.2011.10.012 |
Popis: |
Recently, instances of SCC in Ni-base alloy weld metal of light water reactor components have been reported. Despite the possibility of propagation of SCC crack to the fusion line between low alloy steel (LAS) of pressure vessel and Ni-base alloy of internal structure, a fracture assessment method of dissimilar metal welded joint has not been established. The objective of this study is to investigate a fracture mode of dissimilar metal weld of LAS and Ni-base alloy for development of a fracture assessment method for dissimilar metal weld. Fracture tests were conducted using two types of dissimilar metal weld test plates with semi-elliptical surface crack. In one of the test plates, the fusion line lies around the surface points of the surface crack and the crack tips at the surface points have intruded into LAS. Material ahead of the crack tip at the deepest point is Ni-base alloy. In the other, the fusion line lies around the deepest point of the surface crack and the crack tip at the deepest point has intruded into LAS. Material ahead of the crack tip at the deepest point is LAS. The results of fracture tests using the former type of test plate reveal that the collapse load considering the proportion of ligament area of each material gives a good estimation for fracture load. That is, fracture assessment based on plastic collapse mode is applicable to the former type of test plate. It is also understood that a fracture assessment method based on the elastic-plastic fracture mode is suitable for the latter type of test plate. |
Databáze: |
OpenAIRE |
Externí odkaz: |
|