Evaluation of a new flow cytometry crossmatch procedure for simultaneous detection of cytotoxicity and antibody binding

Autor: Ann-Charlotte Wikström, Mats Alheim, P. K. Paul, Dan Hauzenberger
Rok vydání: 2013
Předmět:
Zdroj: Tissue Antigens. 82:125-130
ISSN: 0001-2815
Popis: In this study we have evaluated an alternative 96-well format flow cytometry based (FCtox) method which enable simultaneous detection of cytotoxicity and human leukocyte antigen (HLA) antibody binding. Comparable results were obtained in side-by-side comparisons with conventional complement-dependent cytotoxicity (CDC) and flow cytometric crossmatch (FCXM) in terms of sensitivity and specificity. There was 91 and 93% agreement between results obtained by FCtox and CDC for T and B cells, respectively. In addition, comparable results were obtained with FCtox IgG and FCXM IgG for both T and B cells. Furthermore, compared with a recently developed and highly sensitive Luminex based C1q assay we obtained close to 90% method agreement with the FCtox assay. Our alternative cytotoxicity and IgG binding assay which exhibit low intra-and inter-assay variation will improve the workflow and speed up the pre-transplant testing and also allow continuous monitoring of assay performance and proper quality assurance.
Databáze: OpenAIRE