Diagnostic value of ultrasound-guided fine-needle aspiration biopsy, core-needle biopsy, and evaluation of combined use in the diagnosis of breast lesions1

Autor: Hiromitsu Ishii, Kaoru Okada, Takehira Yamamura, Shigetoshi Ichii, Takuya Hatada, Yoshinori Fujiwara
Rok vydání: 2000
Předmět:
Zdroj: Journal of the American College of Surgeons. 190:299-303
ISSN: 1072-7515
Popis: Background: To investigate whether ultrasound-guided core-needle biopsy (US-CNB) has more diagnostic value for breast tumors than ultrasound-guided fine-needle aspiration biopsy (US-FNAB) and to evaluate their combined use in patients with breast tumors. Study Design: US-FNAB was carried out in 233 patients with breast tumors (254 lesions); both US-FNAB and US-CNB (combined biopsy) were performed in 81 of these patients (82 lesions). The diagnosis obtained by US-FNAB and US-CNB was compared with the surgical findings and the diagnostic value of US-CNB and combined biopsy were retrospectively evaluated. Results: The sensitivity of US-FNAB was 86.9%, the specificity was 78.6%, and the accuracy was 84%. In contrast, the sensitivity of US-CNB was 86.2%, the specificity was 95.8%, and the accuracy was 89%. The specificity of US-CNB was significantly higher than that of US-FNAB and the inadequate biopsy rate of US-CNB was significantly lower than that of US-FNAB. For combined biopsy, the sensitivity, specificity, and accuracy were all 100%. The sensitivity, specificity, and accuracy of combined biopsy were significantly higher than those of US-FNAB. Conclusions: These findings suggest that US-CNB is more useful than US-FNAB, and that a combination of US-CNB and US-FNAB can markedly improve the preoperative diagnosis of breast cancer.
Databáze: OpenAIRE