Field Performance of PM2.5Federal Reference Method Samplers

Autor: Gary A. Norris, Dave B. Gemmill, Thomas M. Peters, Robert W. Murdoch, Marc Pitchford, Russell W. Wiener, Frank F. McElroy, Robert W. Vanderpool
Rok vydání: 2001
Předmět:
Zdroj: Aerosol Science and Technology. 34:433-443
ISSN: 1521-7388
0278-6826
DOI: 10.1080/02786820116873
Popis: The results of several research field studies were evaluated to estimate the precision and bias of various designated PM2.5 Federal Reference Method (FRM) samplers. Precision was favorable in these carefully conducted research studies where all operational activities were strictly controlled, with an average coefficient of variation (CV) ranging from 2 to 6%. No significant bias was found between the method designations. Comparisons between the designated reference method samplers meet the EPA Equivalent Method Criteria for comparability except for one pair of samplers. In this instance, the