Popis: |
Here is described the development and operation experience of unique unit where hydrogen sulfide is removed from mazut in nitrogen flow. During thus process development the following unparalleled tasks have been solved: initial temperature of sulfur compounds decomposition have been determined, the laboratory have been built, contact devices have been selected, which ensure weight exchange at liquid operating viscosity 80–200 cSt. The correctness of technical solutions is confirmed by many years of unit successful operation. |