Double layers of high-tensioned textile membranes were applied to the completely open-foldable dome for the GREGOR telescope for the first time. Simultaneous climate measurements inside and outside the dome have proven the thermalinsulating capability of this double-layer construction. The GREGOR dome is the result of the continuation of the ESO research on open-foldable domes with textile structures, followed by the research for the DOT dome with high-tensioned textile membranes. It cleared the way to extreme stability required for astronomical practice on high mountain sites with heavy storms and ice formation. The storm Delta with 245 km/h 1-minute mean maximum at the location of the GREGOR caused no problems, nor did other storms afterwards. Opening and closing experiences up to wind speeds of 90 km/h were without problems. New technical developments were implemented and tested at the GREGOR dome, opening the way for application to much larger domes up to the 30 m diameter-class range (© 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim) |