Determination of GLG-V-13, a Novel Antiarrhythmic Agent, in Plasma and Urine by High-Performance Liquid Chromatography

Autor: G. L. Garrison, H. Chen, Kenneth Berlin, Benjamin J. Scherlag, R. Lazzara, J. D. Roder, S. Sangiah, C. L. Chen
Rok vydání: 1994
Předmět:
Zdroj: Journal of Liquid Chromatography. 17:913-927
ISSN: 0148-3919
DOI: 10.1080/10826079408013377
Popis: A sensitive reversed-phase HPLC technique with UV detection has been developed to determine the concentration of GLG-V-13 (3-[4-(1H-imidazol-1-yl)benzoyl]-7-isopropyl-3,7-diazabicyclo[3.3.1]nonane dihydroperchlorate) (I), a novel combined class I and class III antiarrhythmic agent, in dog plasma and urine. Alkalinized plasma and urine samples were extracted with chloroform, and the extracts were reconstituted in methanol. An aliquot was injected on to a Waters HPLC system with a 250 × 4.6 mm Ultramex 5 C6 analytical column (5 μm) and 30 × 4.6 mm Ultramex 5 C6 guard column (5 μm). The elute was detected by a UV detector at 256 nm. Acetonitrile-methanol-37.5 mM phosphate buffer. pH6.8 (27:27:46 v/v) containing 3.6 mM triethylamine was used as the mobile phase. The average extraction recovery was 89% from plasma and 93% from urine. Good lineary (r > 0.999) was observed throughout the range of 8–8000 ng/ml in plasma and in urine with the quantitation limit of 8 ng/ml. Intra- and inter-assay variabili...
Databáze: OpenAIRE