DOI: | 10.3103/s1068364x16090039 |
Popis: | The operation of electrochemical gas analyzers in coke-battery monitoring is considered. The sealing of the battery’s heating system may affect the readings of the gas analyzer. The presence of free hydrogen in the combustion products distorts the readings of the CO cell in the absence of hydrogen compensation. For reasons of reliability, calculation of the SO2 concentration is recommended. |