Evaluation of NO2Measurement Methods for Indoor Air Quality Applications

Autor: Irwin H. Billick, Donald V. Kenny, Chester W. Spicer, Neil P. Leslie, Gerald F. Ward
Rok vydání: 1994
Předmět:
Zdroj: Air & Waste. 44:163-168
ISSN: 1073-161X
DOI: 10.1080/1073161x.1994.10467245
Popis: Measurement of nitrogen dioxide (NO2) and other oxidized nitrogen compounds in indoor environments can present some measurement difficulties not normally encountered in sampling outdoor air. This paper examines three methods that are in current use for monitoring indoor nitrogen dioxide. The methods include ozone-based and luminol-based chemiluminescence, and an electrochemical technique. We have examined these methods for accuracy, linear dynamic range, and interferences. Each of the methods was subject to interference. For indoor measurements, nitrous acid probably represents the most significant interference for the ozone-based chemiluminescence and electrochemical monitors.
Databáze: OpenAIRE