Popis: |
In predicting the electromagnetic consequences of a plasma disruption in a tokamak reactor design, a two-dimensional electromagnetic model of the first wall, blanket, and shield (FWBS) system is typically used. The response to a decaying plasma current is then found to be dominated by a single eddy-current mode, with a single L/R time. Recent experiments with the Fusion ELectromagnetic Induction eXperiment (FELIX) facility at Argonne National Laboratory suggest that such modeling can be used to design against electromagnetic forces and torques, but only if a range of values is used for both tau, the plasma decay time, and tau/sub 0/, the L/R time of the FWBS system. |