Design and Parameter Optimization of a Full-Scale Wastewater Reclamation Plant Including Pretreatment, Electrodialysis Reversal, and Ion Exchange in Steel Manufacturing Processes
Autor: | Yu Chun Su, Mao Sung Yeh, Hsin Hung Ou, Po Hsun Lin |
---|---|
Rok vydání: | 2016 |
Předmět: |
Electrodialysis reversal
Engineering Flocculation Environmental Engineering Waste management Fouling Ion exchange business.industry 02 engineering and technology 021001 nanoscience & nanotechnology Desalination 020401 chemical engineering Wastewater Land reclamation Environmental Chemistry Sewage treatment 0204 chemical engineering 0210 nano-technology business General Environmental Science Civil and Structural Engineering |
Zdroj: | Journal of Environmental Engineering. 142 |
ISSN: | 1943-7870 0733-9372 |
DOI: | 10.1061/(asce)ee.1943-7870.0001118 |
Popis: | The daily demand of demineralized water (DMW) in electrolytic galvanizing line (EGL) in China Steel Corporation (CSC) reached approximately 1,600 m3 as the production line was fully in operation. However, the wastewater produced from the EGL was discharged into the cold-rolling mill wastewater treatment plant even though it had potential for reclamation. This study provides details of design and parameter optimization of a full-scale wastewater reclamation plant for the EGL. Three wastewater streams including hot water rinse, pickling rinse wastewater, and condensate water from the EGL were selected for reclamation. The full-scale wastewater reclamation plant was constructed to equip with coagulation, flocculation, sedimentation, and filtration for pretreatment, and electrodialysis reversal (EDR) and ion exchange (IX) processes for desalination. The pretreatment process can reduce the total iron concentrations in the wastewater from 40–70 ppm to |
Databáze: | OpenAIRE |