Popis: |
We present performance data for Mach-Zehnder optical modulators fielded on the National Ignition Facility (NIF) as a potential signal path upgrade for the South Pole Bang Time diagnostic. A single channel demonstration system has been deployed utilizing two modulators operating in a 90° In phase and Quadrature (I/Q) configuration. X-ray target emission signals are split and fed into two recording systems: a reference CRT based oscilloscope, Greenfield FTD10000, and the dual Mach-Zehnder system. Results of X-ray implosion time (bang time) determination from these two recording systems are compared and presented. |