Rapid Radial T1 and T2 Mapping of the Hip Articular Cartilage With Magnetic Resonance Fingerprinting
Autor: | James S. Babb, James Fishbaugh, Batool Abbas, Jakob Assländer, Martijn A. Cloos, Riccardo Lattanzi, Guido Gerig |
---|---|
Rok vydání: | 2018 |
Předmět: |
Reproducibility
Scanner medicine.diagnostic_test Restricted maximum likelihood Coefficient of variation Cartilage Magnetic resonance imaging computer.software_genre Imaging phantom 030218 nuclear medicine & medical imaging 03 medical and health sciences 0302 clinical medicine medicine.anatomical_structure Voxel medicine Radiology Nuclear Medicine and imaging computer Biomedical engineering Mathematics |
Zdroj: | Journal of Magnetic Resonance Imaging. 50:810-815 |
ISSN: | 1053-1807 |
DOI: | 10.1002/jmri.26615 |
Popis: | Quantitative MRI can detect early changes in cartilage biochemical components, but its routine clinical implementation is challenging. To introduce a novel technique to measure T and T along radial sections of the hip for accurate and reproducible multiparametric quantitative cartilage assessment in a clinically feasible scan time. Reproducibility, technical validation. A seven-compartment phantom and three healthy volunteers. A novel MR pulse sequence that simultaneously measures proton density (PD), T , and T at 3 T was developed. Automatic positioning and semiautomatic cartilage segmentation were implemented to improve consistency and simplify workflow. Intra- and interscanner variability of our technique was assessed over multiple scans on three different MR scanners. For each scan, the median of cartilage T and T over six radial slices was calculated. Restricted maximum likelihood estimation of variance components was used to estimate intrasubject variances reflecting variation between results from the two scans using the same scanner (intrascanner variance) and variation among results from the three scanners (interscanner variance). The estimation error for T and T with respect to reference standard measurements was less than 3% on average for the phantom. The average interscanner coefficient of variation was 1.5% (1.2-1.9%) and 0.9% (0.0-3.7%) for T and T , respectively, in the seven compartments of the phantom. Total scan time in vivo was 7:13 minutes to obtain PD, T , and T maps along six radial hip sections at 0.6 × 0.6 × 4.0 mm voxel resolution. Interscanner variability for the in vivo study was 1.99% and 5.46% for T and T , respectively. in vivo intrascanner variability was 1.15% for T and 3.24% for T . Our method, which includes slice positioning, model-based parameter estimation, and cartilage segmentation, is highly reproducible. It could enable employing quantitative hip cartilage evaluation for longitudinal and multicenter studies. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:810-815. |
Databáze: | OpenAIRE |
Externí odkaz: |