Popis: |
Two experiments have been performed in the VULCANO facility in which prototypic corium has been spread over concrete. In the VE-U7 test, a mixture representative of what can be expected at the opening of EPR reactor-pit gate has been spread on siliceous concrete and on a reference channel in inert refractory ceramic. The spreading progression was not much affected by the presence of concrete and sparging gases. In the VE-U8 test, a UO{sub 2}-ZrO{sub 2} mixture, prototypic of in-vessel corium, has been spread over a lime-siliceous concrete. Although residual power was not simulated in this experiment, up to 2 cm of concrete have been eroded during the test. Results in terms of spreading behaviour, effects of gases, concrete erosion and thermal attack are presented and discussed. (authors) |