CLINICAL EVALUATION OF THE 'GTRIOLEIN BREATH TEST: A CRITICAL ANALYSIS

Autor: A. Kerr Grant, Ross N. Butler, N. J. Gehling, M. J. Lawson
Rok vydání: 1984
Předmět:
Zdroj: Australian and New Zealand Journal of Medicine. 14:111-113
ISSN: 0004-8291
DOI: 10.1111/j.1445-5994.1984.tb04270.x
Popis: Twenty-two hospital patients without gastrointestinal symptoms and fourteen patients with clinically suspected fat malabsorption were studied using the 14C-Triolein Breath Test and three day fecal fat estimation. The 14C-Triolein Breath Test was 100% sensitive and 86% specific for fat malabsorption. Three day fecal fat estimations were 86% sensitive and 91% specific. These data confirm the high sensitivity and specificity obtained using the 14C-Triolein Breath Test. The speed and convenience of the 14C-Triolein Breath Test plus acceptable sensitivity and specificity make this a practical screening test to detect fat malabsorption.