DEVELOPMENT OF CONCEPTUAL TECHNICAL SOLUTIONS AND METHODS OF THEIR IMPLEMENTATION DURING THE DESIGN OF A DUST COAL STEAM GENERATOR OF SUPER-SUPER CRITICAL PARAMETERS OF STEAM 28 MPa / 600 °С / 600 °C FOR 300 MW ENERGY UNIT. PART 2
Autor: | N.I. Dunaevska, B.B. Rokhman, V.G. Vifatnyuk |
---|---|
Rok vydání: | 2021 |
Předmět: | |
Zdroj: | Energy Technologies & Resource Saving. :4-23 |
ISSN: | 2664-3561 2413-7723 |
Popis: | In the second part of the work, using the mathematical model described in first unit, a direct-flow pulverized coal boiler with supercritical steam parameters of 28 MPa /600 °C /600 °C was calculated for a 300 MW power unit at loads of 50–70 %. It is shown that: a) the temperature of contaminated screens 1234 °С in the active combustion zone, where 92 % of the initial fuel burns out, is lower than the temperature of slagging beginning (1268 °С) of ДГ-100 coal, which indicates the slag-free operation of the screens of the lower radiation part (LRP) b) over the entire range of the boiler load change of 50–100 %, the temperature at the exit from the active combustion zone will be higher than the minimum permissible temperature of 1250 °C, below which the flame is attenuated; c) upon transition to 50 % load, the temperature of gases at the outlet from the active combustion zone decreases from 1506 °C to 1342 °C, as a result of which the specific thermal stress of the LRP screens decreases by 1.469 times, while the feed water consumption at the inlet of the boiler falls by 2 times, which leads to an increase in the temperature of the LRP steam, the middle and upper radiation parts, screens of the ceiling and rotating chamber; d) to reduce the thermal stratification of the inlet stage of the secondary steam superheater (ППП1), and as a consequence, the pipe wall temperature, it is necessary to divide the ППП1 surface into two packets, installing an intermediate mixing manifold between them with full steam mixing. Bibl. 5, Fig. 13, Tab. 3. |
Databáze: | OpenAIRE |
Externí odkaz: |