Holographic single-image depth reconstruction

Autor: Simon Hartlieb, Christian Schober, Tobias Haist, Stephan Reichelt
Rok vydání: 2022
Zdroj: EPJ Web of Conferences. 266:10005
ISSN: 2100-014X
Popis: In this article a camera-based single-image sensor is presented, that is able to measure the distance of multiple object points. The experimental results show an accuracy of 8,51 μm within a depth range of 20 mm. The sensor consists of a camera, whose lens is upgraded with a diffractive optical element (DOE). It fulfils two tasks: adding a vortex point spread function (PSF) and replication of the vortex PSFs to a predefined pattern of K spots. Both, shape and rotation of the vortex PSF is sensitive to defocus. By applying the depth reconstruction to each of the K replications and averaging the results, we experimentally show, that the reconstruction of the depth signal can be improved by a factor of up to 3.