Biocular image misalignment tolerance

Autor: Melvyn E. Kalich, R. David Peterson, Terri Lynn Rowe, Corina van de Pol, Clarence E. Rash, Lisa M. Lont
Rok vydání: 2003
Předmět:
Zdroj: SPIE Proceedings.
ISSN: 0277-786X
Popis: Biocular helmet-mounted display (HMD) design flexibility and cost are directly related to image misalignment tolerance standards. Currently recommended tolerance levels are based on highly variable data from a number of studies. This paper presents progress of an ongoing study to evaluate optometric measures sensitive to misalignment in partial-overlap biocular optical systems like that proposed for the Comanche RAH-66 helicopter helmet integrated display sighting system (HIDSS). Horizontal divergent and relative vertical misalignments (offsets) of see-through biocular symbology viewed against a simulated daytime background were chosen for this study. Misalignments within and just beyond current tolerance recommendations were evaluated using pre, pre and post, and during measures of visual performance. Data were obtained from seven experimental and four control subjects. The diplopia responses from experimental and control subjects were essentially the same. However, accommodative facility showed a rate decrement following exposure to both types of misalignment. Horizontal heterophorias showed definite post-misalignment increases. Subject responses to questionnaires universally indicated increased adaptation to (ease with) visual tasks over the testing period.
Databáze: OpenAIRE