Advances in Biomagnetic Liver Susceptometry Allow the Measurement of Liver Iron Concentration with a Room Temperature Sensor
Autor: | Lisa Calvelli, Viktoriia Kolotovska, Ashutosh Lal, Marcela G Weyhmiller, William Avrin |
---|---|
Rok vydání: | 2018 |
Předmět: | |
Zdroj: | Blood. 132:4890-4890 |
ISSN: | 1528-0020 0006-4971 |
DOI: | 10.1182/blood-2018-99-117355 |
Popis: | Introduction: Iron overload is frequently observed in diverse states ranging from thalassemia, sickle cell disease, hereditary hemochromatosis, transfusion-dependent anemias, cancer chemotherapy and chronic liver disease. Management of iron overload depends on the ability to quantify and monitor the patient's iron stores with precision. Organ iron measurement by relaxometry-based MRI techniques has become the current standard. MRI is expensive and has the added limitations of multiple existing methods and reduced dynamic range with 3 Tesla scanners. Liver iron measurements by magnetic susceptometers using superconductive quantum interference device (SQUID) technology are expensive and have limited availability. In this study an improved low-cost device, the room-temperature susceptometer (RTS, Insight Magnetics, San Diego, CA), was tested against the Model 5700 Ferritometer ® 3-Channel SQUID BioSusceptometer System (Tristan Technologies, Inc. San Diego, CA). Both systems quantify liver iron concentration (LIC) using bulk magnetic susceptibility. Where the SQUID uses an ultra-stable sensing system immersed in liquid helium, the RTS cancels the temperature and magnetic-field fluctuations inherent in an apparatus that works at room temperature. The RTS uses three main techniques to sense the very weak magnetic field produced by liver iron: (a) oscillatory magnetic fields that can be detected with high sensitivity using coils of ordinary copper wire, (b) field-producing and field-sensing coils to cancel the signal due to the applied magnetic field, and (c) movement of the sensing unit periodically toward and away from the patient so as to distinguish the patient's magnetic field response from the interfering signal caused by temperature fluctuations in the sensing system. Methods: This study compared measurements of LIC from RTS to those by the SQUID. The RTS in this study was modified from an earlier model to make the baseline reading more stable, and to increase the accuracy of the water reference measurement to which the patient's magnetic response is compared. The magnetic-field source and sensing coils were enlarged to increase the signal of the liver compared with that of the overlying tissue. LIC was measured once on the SQUID and once on the RTS at a single visit. Using ultrasound imaging, optimum liver measurement position was determined and marked with an x-y-positioning and z-distance sensing Locator Loop (Positronic Systemtechnik GmbH, Germany). The locator loop remained attached to the patient for measurements with both devices to preserve measurement location. LIC calculation was corrected for the susceptibility and geometry of the overlying tissue. Measurement results from SQUID and RTS were analyzed independently by two investigators. Results: Thirteen adults (10 with transfusion-dependent thalassemia and 3 controls) with body mass index (BMI) Conclusion: This study shows that, with the recent improvements in the RTS technology, LIC measurements now closely align with those using SQUID. The remaining difference between the two methods likely results from the models used to compensate for the overlying tissue. Further comparison of RTS to SQUID and MRI-based methods in diverse iron overload states is warranted in a larger study. This work may ultimately make low-cost noninvasive measurement of iron overload accessible to the large number of patients in the US, and to resource-limited countries around the world. Disclosures Lal: Bluebird Bio: Research Funding; Insight Magnetics: Research Funding; Terumo Corporation: Research Funding; Novartis: Research Funding; Celgene Corporation: Research Funding; La Jolla Pharmaceutical Company: Consultancy, Research Funding. Avrin:Insight Magnetics: Employment, Other: Proprietor of company developing the study device, Patents & Royalties: Own rights to patents on the study device. Weyhmiller:Insight Magnetics: Research Funding. |
Databáze: | OpenAIRE |
Externí odkaz: |