Safety And Efficacy Of Achieving Single-Digit Intraocular Pressure Targets With Filtration Surgery In Eyes With Progressive Normal-Tension Glaucoma
Autor: | Scott K. Schultz, David S. Greenfield, Wei Shi, Shawn M Iverson |
---|---|
Rok vydání: | 2016 |
Předmět: |
Intraocular pressure
medicine.medical_specialty genetic structures business.industry medicine.medical_treatment Glaucoma Retrospective cohort study Mean age Light perception medicine.disease eye diseases 03 medical and health sciences Ophthalmology 0302 clinical medicine Filtration surgery Normal tension glaucoma 030221 ophthalmology & optometry Medicine Trabeculectomy sense organs business 030217 neurology & neurosurgery |
Zdroj: | Journal of Glaucoma. 25:217-222 |
ISSN: | 1057-0829 |
DOI: | 10.1097/ijg.0000000000000145 |
Popis: | PURPOSE Whereas achieving intraocular pressure (IOP) targets ≤ 10 mm Hg typically requires surgical intervention, we sought to examine the safety and efficacy of trabeculectomy in normal-tension glaucoma (NTG). METHODS Patients with progressive NTG undergoing trabeculectomy with preoperative IOP ≤ 15 mm Hg during the 12-month period before surgery were identified at a single academic institution. Failure was defined as IOP reduction |