Popis: |
This paper summarizes the effects of the pressure sensor shape on the dynamic oscillating pressure measurements when the pressure wave modulating along the steam/air flow path is to be characterized. In the study presented in the paper, a three-dimensional CFD model of the external flow around the protruding, dome-shaped sensor was developed to evaluate the effects of the sensor shape on the external flow pattern, and the detailed flow patterns were studied with this protruding, dome-shaped sensors and compared with the flow patterns for the flush mounted sensors. Then, a one-dimensional analysis was done to predict that the dynamic pressures measured with the protruding sensor do not require significant correction, and this was later supported by wind tunnel tests. The amplitude of the dynamic pressure measured on the protruding sensor was determined to be ranging from 0 to 8% higher than measured by a flush mounted pressure sensor. The frequency of the pressure wave is not affected by the presence of the protrusion.Copyright © 2006 by ASME |