DDT in methane-air mixtures
Autor: | V.I. Alekseev, T. H. Kim, Mike Kuznetsov, Gaby Ciccarelli, S.B. Dorofeev, Yu. Yankin |
---|---|
Rok vydání: | 2002 |
Předmět: | |
Zdroj: | Shock Waves. 12:215-220 |
ISSN: | 1432-2153 0938-1287 |
DOI: | 10.1007/s00193-002-0155-0 |
Popis: | Experimental results from a study on the critical condition for deflagration-to-detonation transition (DDT) in methane-air mixtures are presented. Experiments were carried out at 293 K and 1 atm using methane-air mixtures with methane concentrations ranging from 5.5 to 17% vol. The tests were performed in detonation tubes with inner-diameters of 174 mm and 520 mm. Detonation cell widths \(\lambda\) were determined in the tests for a range of methane concentrations. The results of DDT tests indicate that for a tube cross-sectional area blockage ratio (BR) of 0.3 the critical condition for DDT can be characterized by the \(d/\lambda = 1\) criterion. However, for a BR = 0.6 the critical value \(d/\lambda\) was significantly higher. The data also show that the critical condition for DDT can be described by \(L/\lambda = 7\), where L is the characteristic length-scale of the channel volume between orifice plates. This length-scale is defined by a grouping of the orifice plate dimensions (inner and outer-diameter) and plate spacing. |
Databáze: | OpenAIRE |