Integral Testing of the AP600 Passive Emergency Core Cooling Systems
Autor: | L K Lau, L E Hochreiter, L E Conway, S V Fanto |
---|---|
Rok vydání: | 1993 |
Předmět: | |
Zdroj: | Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy. 207:259-268 |
ISSN: | 2041-2967 0957-6509 |
DOI: | 10.1243/pime_proc_1993_207_048_02 |
Popis: | In support of the development of AP600, Westinghouse is conducting two integral systems tests to examine the performance of the passive safety systems. A full-height, full-pressure test is being performed to simulate a small loss-of-coolant, steam generator tube rupture and large steam line break events. A one-quarter scale, low-pressure test is being performed to simulate transients with emphasis on the transition to the natural circulation post-accident, long-term cooling mode and to demonstrate the long-term cooling capability. Each of the tests will provide detailed experimental results for verification of the accident analysis computer codes. |
Databáze: | OpenAIRE |
Externí odkaz: |