Monte Carlo Calculations for the Shielding Design of Beam Injection and Extraction Areas at the 3-GeV Synchrotron in J-PARC
Autor: | Teruo Abe, Yoshihiro Nakane, Hiroshi Nakashima |
---|---|
Rok vydání: | 2009 |
Předmět: |
Physics
Nuclear and High Energy Physics Astrophysics::High Energy Astrophysical Phenomena 020209 energy Physics::Medical Physics Monte Carlo method Shields Proton Synchrotron Particle accelerator 02 engineering and technology Condensed Matter Physics Synchrotron law.invention Nuclear physics 020303 mechanical engineering & transports 0203 mechanical engineering Nuclear Energy and Engineering law Electromagnetic shielding 0202 electrical engineering electronic engineering information engineering Physics::Accelerator Physics J-PARC Beam (structure) |
Zdroj: | Nuclear Technology. 168:519-523 |
ISSN: | 1943-7471 0029-5450 |
DOI: | 10.13182/nt09-a9236 |
Popis: | Radiation shielding calculations were performed for the shielding design around beam injection and beam extraction areas at the 3-GeV proton synchrotron in the Japan Proton Accelerator Research Complex (J-PARC) with the PHITS Monte Carlo code. Prompt dose rates outside the shields were obtained from calculated neutron energy spectra and flux-to-dose conversion coefficients prepared for the shielding design in J-PARC. The thicknesses of shields were determined from the comparison results of the prompt dose rates with the criteria of dose limit for the design in J-PARC. |
Databáze: | OpenAIRE |
Externí odkaz: |