2020 guided wave inspection of California Department of Water Resources tainter gate post-tensioned trunnion anchor rods : Oroville Dam

Autor: Jason Ray, Clayton Thurmer
Rok vydání: 2022
DOI: 10.21079/11681/43762
Popis: The Engineering and Test Branch within the Division of Operations and Maintenance of the California Department of Water Resources (DWR) and U.S. Army Corps of Engineers (USACE), Sacramento District, tasked the Sensor Integration Branch (SIB) at the Engineer Research and Develop-ment Center (ERDC) to perform non-destructive testing (NDT) on the trunnion anchor rods at Oroville Dam through the use of ultrasonic guided waves. This is the third year of this NDT. The results of the testing are presented along with qualitative analysis in determining whether a rod is in-tact or compromised. Analysis is based upon the expected results from other rods at the site, knowledge of rod response at other sites, data gathered from the trunnion rod research test bed at the ERDC, and comparison to the previous year’s effort.