performance of evaporative cooling for mid-south gestation housing

Autor: G. R. Parker, Robert L. Fehr, Samuel G. McNeill, J. N. Walker
Rok vydání: 1983
Předmět:
Zdroj: Transactions of the ASAE. 26:0219-0222
ISSN: 2151-0059
DOI: 10.13031/2013.33907
Popis: Afield study determined the effectiveness of an evap-rative pad cooling system in a swine gestation house. Theoretical procedures predicted the performance of the cooling system and the building performance. Predicted values were compared with observed temperature modifications of the ventilation air.