Suppression and utilization of spurious pulse occurrence in organic GM-counters

Autor: Yasutomo Ozawa, Ryuji Igarashi, Hideo Akagami, Yuichi Narita
Rok vydání: 1979
Předmět:
Zdroj: Nuclear Instruments and Methods. 158:161-168
ISSN: 0029-554X
DOI: 10.1016/s0029-554x(79)91445-9
Popis: The authors have made a study of suppression and utilization of spurious pulse occurrence in organic GM-counters. Almost all spurious pulses in the organic GM-counter are the delayed pulses which occur being dependent upon the radiation intensity. The occurrence rate of the delayed pulses against the radiation intensity is affected by the intensity of the electric field in the vicinity of the cathode of the GM-counter. The occurrence of the delayed pulses can be suppressed when the electric field in the vicinity of the cathode is kept at high value. On the contrary, the occurrence of the delayed pulses can be utilized for the dosimetry of the pulsed radiation by means of increasing the space of the weak electric field in the GM-counter.