iSMORE: An Iterative Self Super-Resolution Algorithm
Autor: | Jerry L. Prince, Can Zhao, Yongsoo Kim, Seoyoung Son |
---|---|
Rok vydání: | 2019 |
Předmět: |
0303 health sciences
medicine.diagnostic_test Computer science business.industry Noise reduction Pattern recognition Magnetic resonance imaging Function (mathematics) Convolutional neural network 030218 nuclear medicine & medical imaging 03 medical and health sciences 0302 clinical medicine Aliasing Consistency (statistics) Microscopy Fluorescence microscope medicine Medical imaging Artificial intelligence Enhanced Data Rates for GSM Evolution business 030304 developmental biology Interpolation |
Zdroj: | Simulation and Synthesis in Medical Imaging ISBN: 9783030327774 SASHIMI@MICCAI |
Popis: | In 3D medical imaging, images with isotropic high resolution (HR) are almost always preferred. In practice, however, many acquired images, including magnetic resonance imaging (MRI) and fluorescence microscopy, have HR in the in-plane directions and low resolution (LR) in the through-plane direction. The blurriness and aliasing artifacts that result cannot be solved by simple interpolation. Instead, many researchers have proposed super-resolution algorithms including state-of-art convolutional neural network (CNN)-based methods that require matched training data that have paired LR/HR examples. Since these data are often unavailable in practice, self super-resolution algorithms that do not need external training data have also been proposed. These self super-resolution methods assume that the in-plane slices are HR, and can therefore be used as HR training data. By degrading them into LR images, 2D CNNs can be trained and then used to restore the images in the through-plane. However, there are two issues with these approaches. The first one is that the assumption of HR in-plane slices is actually not solid since these thick in-plane slices are averaged true HR thin slices. Training on thick slices is equivalent to training on averaged true HR images, which is suboptimal. The second one relates to the 2D CNNs used on 3D volume, which cannot guarantee slice consistency. Regarding both issues as well as the generalizability of algorithm, we made four contributions. We show in this paper that one of the existing 2D CNN-based self super-resolution methods, SMORE, can be further improved by iteratively applying it using 2D or 3D networks, yielding 2D and 3D iSMORE. This iterative framework improves training data from thick slices to thinner slices after each iteration, thus improves super-resolution accuracy after each iteration, and solves the first issue. The second contribution is that it uses a 3D network to preserve slice consistency. The third contribution is the use of an edge-based loss function and noise reduction to enhance the performance. Finally, we perform iSMORE on both MRI and two-photon fluorescence microscopy, which demonstrates its generalizability. |
Databáze: | OpenAIRE |
Externí odkaz: |