Popis: |
Nowadays, improving the efficiency of power plants by utilizing secondary energy resources is gaining more attention in the energy sector. In this paper, the combined cycle gas turbine (CCGT-420T) was considered, where exhaust heat from the main and auxiliary equipment is utilized, and sent to a water supply system through a closed-circuit heat exchanger, as a result, the heat transferred (Q = 6.4 MW) is rejected into the environment through a cooling tower. Moreover, an effective modelling method for utilizing heat in a closed cycle, using a steam compressing heat pump unit (HPU) is proposed. In addition, a calculation of the effectiveness of utilizing secondary energy resources depending on the number of HPU stages. |