Unit Process Energy Requirements for Steam Infusion UHT Milk Processing

Autor: B. C. Frey, L. E. Stewart, D. I. Chandarana, J. F. Mattick
Rok vydání: 1984
Předmět:
Zdroj: Transactions of the ASAE. 27:1956-1959
ISSN: 2151-0059
DOI: 10.13031/2013.33077
Popis: Asteam infusion ultra-high temperature (UHT) system was used to sterihze raw milk at 138, 143, 148, and 154°C. Energy consumption/recovery of various unit operations of the UHT system and a conventional high-temperature-short-time (HTST) pasteurization system were determined and compared. The UHT system consumed between 476 and 570 kJ/kg milk. The HTST system, in comparison, consumed between 120 and 131 kJ/kg milk. The energy consumption/recovery of the regenerator, prcheater (heater), homogenizer, and cooler were comparable for both systems. The sterihzer utiUzed between 71 and 74^0 of the total energy required by the UHT system. Heat absorbed by the vacuum cham.ber vapor condensing water, between 243 and 311 kJ/kg milk, represents the heat recovery potential for the steam infusion UHT system.