Mesure de la permittivité complexe de liquides de référence pour la détermination du débit d’absorption spécifique (DAS)
Autor: | A. Litwin, D. Allal |
---|---|
Rok vydání: | 2014 |
Předmět: | |
Zdroj: | Revue française de métrologie. :21-27 |
ISSN: | 1776-3215 1772-1792 |
DOI: | 10.1051/rfm/2014002 |
Popis: | This paper presents our work for the measurement of the complex permittivity of liquids, carried out in the framework of a European Metrology research project entitled “Traceable measurement of field strength and SAR for the Physical Agents Directive”. One of the aims of this project was to establish the traceability of the specific absorption rate measurements to the SI up to 10 GHz. We use a vector network analyser to measure the S 21 parameter of coaxial cells containing the liquid under test (a reference liquid or an equivalent tissue liquid). The method does not require the network analyser to be calibrated in terms of impedance. In fact, only the length of the coaxial cell and the working frequency need to be known. |