The micro-shear bond strength of two different repair systems to indirect restorative materials

Autor: Najafova Lamia, Üşümez Aslihan, Atay Ayșe, Kurtulmus Huseyin Mehmet
Rok vydání: 2020
Předmět:
Zdroj: STOMATOLOGY EDU JOURNAL. 7:233-241
ISSN: 2502-0285
2360-2406
DOI: 10.25241/stomaeduj.2020.7(4).art.1
Popis: Introduction The aim of this study was to evaluate the micro-shear bond strength (μSBS) of different repair systems (Clearfil Repair, iGOS Repair) to restorative materials for CAD/CAM (Cerasmart, Lava Ultimate, InCoris TZI , VITA Suprinity, VITA Mark II, IPS e.max CAD, IPS Empress CAD). Methodology The 140 1.2 mm-thick specimens were prepared from CAD/CAM blocks (n=20) and thermocycled (10,000 cycles, 5–55°C, dwell time 20s). The specimens were randomly divided into two groups according to the repair system: Clearfil Repair (40% phosphoric acid+mixture of Clearfil Porcelain Bond Activator and Clearfil SE Bond Primer+Clearfil SE Bond+CLEARFIL MAJESTY ES-2) and iGOS Repair (40% phosphoric acid+ Multi Primer LIQUID+ iGOS Bond+ iGOS Universal). The composite resins were polymerized. All specimens were stored in distilled water at 37°C for 24 hours. The μSBS test was performed with a micro-shear testing machine (at 1 mm/min). The data were analyzed using two-way ANOVA, Tukey’s multiple comparison tests at a significance level of p
Databáze: OpenAIRE