Stabilization of the phase-space portrait parameters of a hydrogen ion beam
Autor: | A. S. Belov, O. T. Frolov, V. N. Zubets, E. S. Nikulin, S. E. Golubovski |
---|---|
Rok vydání: | 2017 |
Předmět: | |
Zdroj: | Instruments and Experimental Techniques. 60:159-166 |
ISSN: | 1608-3180 0020-4412 |
DOI: | 10.1134/s0020441217020166 |
Popis: | This investigation carried out variations in the transverse phase-space portrait of an ion beam during a 200-μs pulse of a proton injector in the linear accelerator at the Institute for Nuclear Research. The parameters of the accelerated 400-keV beam at the entrance into the beam transport channel and the beam from the ion source were measured. Numerical simulation of ion-beam acceleration in the proton injector was performed. The noiseless mode of beam generation in the duoplasmatron was obtained. The generator of the duoplasmatron discharge current with a discharge current instability of ±1% or less was developed and put into operation. A compensated resistive-capacitive voltage divider was used in the accelerating tube. The beam emittance measurements showed that the variations in the phase-space portrait of the beam from the upgraded injector during the 200-μs pulse were absent within the measurement accuracy. The normalized emittance for 90% of the beam current was 0.15π × cm × mrad at an ion current of 65 mA. |
Databáze: | OpenAIRE |
Externí odkaz: |