Autor: |
Richard T. Kouzes, Christian Cowles, G. R. Imel, Zheming Wang, Sean M. Robinson, Edward R. Siciliano, Sean C. Stave, Azaree T. Lintereur, Richard S. Behling |
Rok vydání: |
2015 |
Předmět: |
|
Zdroj: |
2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). |
DOI: |
10.1109/nssmic.2015.7581914 |
Popis: |
Alternatives to 3He are being investigated for gamma-ray insensitive neutron detection applications, including plutonium assay. One promising material is lithium-6 fluoride with silver activated zinc sulfide 6LiF/ZnS(Ag) in conjunction with a wavelength shifting plastic. Doping the 6LiF/ZnS(Ag) with nickel (Ni) has been proposed as a means of reducing the decay time of neutron signal pulses. This research performed a pulse shape comparison between Ni-doped and non-doped 6LiF/ZnS(Ag) neutron pulses. The Ni-doped 6LiF/ZnS(Ag) had a 32.7% ± 0.3 increase in neutron pulse height and a 32.4% ± 0.3 decrease in neutron pulse time compared to the non-doped 6LiF/ZnS(Ag). Doping 6LiF/ZnS(Ag) with nickel may allow neutron detector operation with improved signal to noise ratios, and reduced pulse pileup affects, increasing the accuracy and range of source activities with which such a detector could operate. |
Databáze: |
OpenAIRE |