Experimental investigation of transient effects of thermoelectric temperature transducers in the IVV-2M reactor
Autor: | V. K. Prozorov, L. I. Men'kin, V. I. Donetskii, V. I. Uvarov, V. M. Sumerin, Yu. A. Safin, V. I. Vlasov, S. P. Ledov, I. P. Maslov, V. I. Nalivaev, I. E. Dobrovinskii, S. V. Priimak, B. N. Oleinik, B. V. Lysikov, A. A. Fraktovnikova |
---|---|
Rok vydání: | 1986 |
Předmět: | |
Zdroj: | Soviet Atomic Energy. 60:17-21 |
ISSN: | 1573-8205 0038-531X |
Popis: | The first stage of investigations was carried out on the IVV-2M reactor to clarify the influence of transient effects on temperature measurement. The experiments were made on the basis of in-reactor thermoelectric temperature transducer (TTT) calibration in reference points. Temperatures of melting (hardening) of aluminum/copper were chosen as reference points. A figure shows variations of transient deviations and of ionization-chamber signal with time at safety trip. The experimental results demonstrated the absence of significant transient deviations in TTT readings. |
Databáze: | OpenAIRE |
Externí odkaz: |