Autor: | R. Gustafson, D. J. Summers, Andrew Beretvas, H. S. Budd, L. M. Cremaldi, C. Zhao, R. Walker, H. Whitaker, Geoffrey Zhang, P. de Barbaro, E. E. Bartosz, R. W. Kadel, G. W. Foster, Jim Freeman, R. Tokarek, Q. Fan, C. Hojvat, Y. H. Zhou, J. Huston, M. Shappirio, C. Leggett, A. Byon-Wagner, J.J. Reidy, Vasken Hagopian, Virgil E Barnes, A. Bodek, Donald E. Groom, D. Green, W. K. Sakumoto |
---|---|
Rok vydání: | 1993 |
Předmět: |
Physics
Nuclear and High Energy Physics Physics::Instrumentation and Detectors Hadron Linearity Calorimeter Computational physics Nuclear physics Sampling (signal processing) Stack (abstract data type) Calibration High Energy Physics::Experiment Instrumentation Beam (structure) Energy (signal processing) |
Zdroj: | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 329:50-61 |
ISSN: | 0168-9002 |
Popis: | The energy resolution, linearity and e/π response of model SDC calorimeter configurations were measured. They consisted of a fine sampling lead electromagnetic (e.m.) compartment and either a lead or iron hadronic (HAD) compartment. The data indicate that the lead-scintillator and iron-scintillator hadronic calorimeters have comparable resolutions and linearity after a relative weighting of signals from the EM and HAD compartments is made. |