CFD Predictions of Soot & CO Emissions Generated by a Partially-Fueled 9-Element Lean-Direct Injection Combustor

Autor: Changju T. Wey, Manthena S. Raju
Rok vydání: 2020
Předmět:
Zdroj: AIAA Scitech 2020 Forum.
DOI: 10.2514/6.2020-2088
Popis: A study was undertaken to investigate the CO & soot emissions generated by a partially-fueled 9- element LDI (Lean-Direct Injection) combustor configuration operating in the idle range of jet engine conditions. In order to perform the CFD analysis, several existing soot/chemistry models were implemented into the OpenNCC (Open National Combustion Code). The calculations were based on a Reynolds-Averaged Navier Stokes (RANS) simulation with standard k-epsilon turbulence model, a 62- species jet-a/air chemistry, a 2-equation soot model, & a Lagrangian spray solver. A separate transport equation was solved for all individual species involved in jet-a/air combustion. In the test LDI configuration we examined, only five of the nine injectors were fueled with the major pilot injector operating at an equivalence ratio of near one and the other four main injectors operating at an equivalence ratio near 0.55. The calculations helped to identify several reasons behind the soot & CO formation in different regions of the combustor. The predicted results were compared with the reported experimental data on soot mass concentration (SMC) & emissions index of CO (EICO). The experimental results showed that an increase in either T3 and/or F/A ratio lead to a reduction in both EICO & SMC. The predicted results were found to be in reasonable agreement. However, the predicted EICO differed substantially in one test condition associated with higher F/A ratio.
Databáze: OpenAIRE