Experience gained from carrying out ultrasonic cleaning of fuel assemblies and control and protection system assemblies in the Novovoronezh NPP unit 3
Autor: | V. A. Shvarov, V. I. Gorburov, S. L. Vitkovskii |
---|---|
Rok vydání: | 2014 |
Předmět: | |
Zdroj: | Thermal Engineering. 61:107-116 |
ISSN: | 1555-6301 0040-6015 |
DOI: | 10.1134/s0040601514020050 |
Popis: | A growth of deposits on fuel assembly elements was revealed during operation of the Novovoronezh NPP Unit 3 starting from 1997. This growth caused progressive reduction of coolant flow rate through the reactor core and increase of pressure difference across the assemblies, which eventually led to the need to reduce the power unit output and then to shut down the power unit. In view of these circumstances, it was decided to develop an installation for ultrasonic cleaning of fuel assemblies. The following conclusions were drawn with regard of this installation after completion of all stages of its development, commissioning, and improvement: no detrimental effect of ultrasound on the integrity of fuel assemblies was revealed, whereas the cleaning effect on the fuel assemblies subjected to ultrasonic treatment and improvement of their thermal-hydraulic characteristics are obvious. With these measures implemented, it became possible to clean all fuel assemblies in the core in 2011, to achieve better thermal-hydraulic characteristics, and to avoid reduction of power output and off-scheduled outages of Unit 3. |
Databáze: | OpenAIRE |
Externí odkaz: |